The equations of the “Boundaries and late-time behaviour” lessons in “Well testing and pressure transient analysis”, with their conditions and units, and what each symbol means in them.
Holds when: The fault is a straight sealing boundary through the whole thickness of a homogeneous reservoir, and the disturbance has not reached any other boundaries. For the well itself the logarithmic approximation holds (tD>25), and wellbore storage is over. The image is a line source at a distance 2L. The argument of E1 is (2LD)2/(4tD)=LD2/tD.
Holds when: The first line holds while ηt/L2<0.2, once wellbore storage is over. The second line holds at ηt/L2≫1. Its slope differs from 2m by less than 5% only after ηt/L2≈10. The skin enters the second line once, because only the real well has a pressure drop across the skin.
Distance to the fault from the intersection time of the lines
tx=kγϕμctL2⇒L=γϕμctktx,γ=1.781
SI
Holds when: Both lines are identified reliably, and the second is drawn through points where the slope has really doubled. ϕ and ct are known independently. Their error passes into L as a square root.
The derivative step at a sealing fault, and the distance from a single point on it
Δp′=me[1+exp(−ηtL2)]⇒L=ηtlnΔp′−meme
SI
Holds when: The reservoir is homogeneous and there is one straight sealing fault. Wellbore storage is over, and me and k are known from the first plateau. We take points in the middle of the step, where Δp′/me is between 1.2 and 1.7. At the start and at the end of the step, small errors in the derivative change L greatly.
Holds when: The first plateau is hidden by wellbore storage, and the doubled plateau has formed. The distance L is known independently, because we cannot find it from such a record. The reservoir is homogeneous, and the fault is straight and sealing.
Holds when: Before start-up the pressure in the reservoir was pi. The rate stays constant during tp. For the well itself the logarithmic approximation holds, and wellbore storage is over. There are no other boundaries.
Distance to the fault from the intersection of the Horner lines
L=γηΔtex,Δtex=tp+ΔtxtpΔtx
SI
Holds when: The fault was felt long before shut-in: L2≪ηtp. Then E1(L2/(ηtp)) can be replaced by a logarithm. Both Horner lines have fully formed. A second Horner line that has not fully formed gives too small a value of L, as in a drawdown test.
Largest deviation of the build-up from the line, and the maximum distance at which a fault can be detected
δpmax=4πeϕcthL2qBtp⇒Lmax=4πeϕcthδpqBtp
SI
Holds when: The fault was not felt during production: ηtp≪L2. In practice the formula already works for L2>3ηtp. The record lasts at least L2/η after shut-in. The reservoir is homogeneous. There are no other disturbances, such as neighbouring wells in operation or gauge drift (a slow creep of the gauge reading).
Holds when: The boundaries are straight sealing planes through the whole thickness of a homogeneous reservoir. Images describe exactly a channel and a wedge with an angle 180∘/n. Wellbore storage is over. The images are line sources (dj is much larger than the wellbore radius). The rate is constant. For a build-up we add up the same terms by superposition, and we allow for the producing time (Pressure build-up analysis).
Holds when: The walls are parallel sealing boundaries through the whole thickness of a homogeneous reservoir; along the channel the reservoir is unbounded. The disturbance has reached both walls: the derivative lies on a line with slope ½ (by the table below, at ηt/W2 from 0.1 to 0.4, depending on the position of the well). A constant rate; wellbore storage is over.
The channel width from the slope of the line Δp against √t
W=hmLqBπkϕctμ
SI
Holds when: The line is drawn through the points where the derivative already has a slope of ½. The permeability was found independently: from the radial flow of the same record or from other data. ϕ, ct and h are known: their error enters W as 1/ϕct and 1/h.
A build-up in a channel in the section of linear flow
pi−pws=mL(tp+Δt−Δt)
SI (metric oilfield units: MPa, h, mL in MPa/√h)
Holds when: A constant rate during tp; before start-up the pressure in the reservoir was pi. Both tp and Δt are large enough for both terms of the superposition to be in the linear-flow section (ηΔt/W2 not less than 0.1–0.4 by the table above).
The late level of the derivative in a wedge, and the angle from it
Δp∞′=θ360∘me⇒θ=360∘Δp∞′me
any equal units of pressure
Holds when: Two straight sealing faults through the whole thickness of a homogeneous reservoir meet at one point (in plan view). The disturbance has reached no other boundaries. The level has really been reached: on the way to it, the derivative is still lower, and the angle from it comes out too large. The angle is less than 180°: the well is inside an “acute” (less than 90°) or “obtuse” (more than 90°) angle, not beyond a bend of a fault.
Holds when: The shortfall is small, no more than 15–20%. At a larger one, the next terms of the expansion matter, and the estimate of R∞ comes out too low and the angle too large. The derivative from measurements has no noticeable noise: the difference r2−r1 is small, and its error strongly affects the result. The disturbance has reached no other boundaries than the two faults.
Holds when: the boundaries are straight and sealing, through the whole thickness of a homogeneous reservoir; the images are line sources (dj≫rw) the rate is constant, wellbore storage is over, tD>25 for images that go off to infinity (channels), we add terms until they become negligible
Holds when: all the boundaries are straight sealing planes, parallel to x or y, through the whole thickness of a homogeneous reservoir the well is a line source, wellbore storage is over, and the rate is constant
A well in a channel closed at one end: late linear flow
Δp=2mLt+2πkhqBμ(S+Sch)−khWqBμL3,Δp′=mLt
SI
Holds when: the walls and the closed end are sealing planes through the whole thickness of a homogeneous reservoir; in the other direction the channel is unbounded the closed end is farther away than the width of the channel (L3>W), and ηt≫L32, so the closed end has long been “felt”; wellbore storage is over, and the rate is constant
Distance to the closed end of the channel: from a point of the derivative and from the intersection of the lines of Δp against √t
L3=ηtlnr−11,r=21mLtΔp′(t);L3=πηtx
SI
Holds when: the record contains the linear flow of the open channel. We draw the line 21mLt along it on the derivative, and the line with slope mL on the plot of Δp against t the closed end is farther away than the width of the channel; the permeability is known from the radial-flow plateau the second formula holds if the late line has really been reached. If we draw a line with slope 2mL through the last reading at time tend, it gives Lx=L3−L32/πηtend (the correction is in the example)
A well at a sealing boundary as a well with a doubled rate
pwD=2pD∗(tD)−lnrw2δ+S
dimensionless
Holds when: the boundary is straight and sealing; δ is small compared with the other dimensions of the system the time is longer than a few δ2/η: the image at distance 2δ has already merged with the well (the derivation is in the advanced section)
Holds when: before start-up the pressure in the formation was pi; the rate is constant during tp; for the well itself the logarithmic approximation holds, and wellbore storage is over for channels the sum is infinite but converges: distant images give equal terms at tp+Δt and at Δt, and the difference vanishes
Holds when: during the producing time the closed end has hardly been felt: ηtp≪L32 (in practice it is enough that L32>3ηtp) the closed end is farther away than the width of the channel, and by the time Δtmax the channel has long been in linear flow a homogeneous formation; no gauge drift and no interference from neighbouring wells
Holds when: the zone is thin compared with the distance to the well, and it stores no fluid single-phase flow; the zone is the same along the whole length and thickness of the fault on both sides there is a formation with the same properties and thickness
dimensionless; kf and k, and lf and L, in the same units
Holds when: the thickness of the formation is the same on both sides of the fault (otherwise the numerator and the denominator contain their own kh) the fluid has the same properties on both sides
Holds when: the fault is a straight semipermeable barrier through the whole thickness of a homogeneous formation that is the same on both sides; there are no other boundaries for the well itself the logarithmic approximation holds, and wellbore storage is over the image and the leak are line sources (L is much larger than the well radius)
the remainder and Sf are dimensionless; Δp and me are in the same pressure units; natural logarithm
Holds when:tDL≫1/α2 and tDL≫1: the remainder of the derivative is small; the formula for the remainder is approximate (it overstates it by a few per cent) the disturbance has not reached any other boundaries
Holds when: single-phase flow; the zone is the same over the area A the jump across the zone is smaller than the difference of the average pressures in the blocks: on the way to the fault and away from it, some pressure drop is also lost in the blocks themselves
Holds when: neighbouring cells have the same size and permeability; for different cells, we add the half-resistances Δxi/(2ki) separately the width of the zone is small compared with the cell
area of the section: its length along the fault (the strike) times the thickness of the formation that is in contact across the fault, m²Partially communicating faults
rate, formation volume factor (reservoir volume per unit of surface volume), viscosity, permeability, thickness, porosity, total compressibility, m³/s, m³/m³, Pa·s, m², m, —, 1/PaSeveral boundaries: parallel faults and wedge-shaped blocks