Skip to content
Brent$117.6Gas TTF$1,192USD453.87 ₸
MunaiHub
Well testingTransient testing: fundamentals Advanced 20 min read

Dimensionless well solutions: skin, radius of investigation and units

Dimensionless well solutions are solutions of the diffusivity equation (the equation that describes how pressure spreads through a reservoir) for a single well, written in dimensionless variables (variables with no units). We measure pressure in “units” of the radial pressure drop qBμ/(2πkh)qB\mu/(2\pi kh), time in units of rw2/ηr_w^2/\eta, and distance in well radii. One curve pD(tD)p_D(t_D) describes any well that has the same dimensionless parameters: the skin (a number that shows how much the zone right around the well helps or hinders flow), the wellbore storage coefficient, and the distances to the boundaries. This lesson shows how the solutions represent the well radius and the skin, how far a test “sees”, how the radius of investigation differs from the radius of drainage, and how to convert the solutions to metric and oilfield units.

Why it matters

All type curves (ready-made curves that we match to test data), interpretation programs and well-test formulas are built on dimensionless solutions. To use them, we must be able to do three things. We must convert a dimensionless point into hours and megapascals. We must understand which simplified picture of the well is built into the solution, and when it stops working. And we must answer planning questions: what part of the reservoir the test has covered, whether it will see a boundary, and what productivity to expect from the well when the transient process is over.

Quick refresher

  • There is one dimensionless solution for all wells. Pressure is in “units” of qBμ/(2πkh)qB\mu/(2\pi kh), time is in units of rw2/ηr_w^2/\eta (fractions of a second), and distances are in well radii. A few groups then describe the well and the reservoir: SS, CDC_D, reDr_{eD}, LDL_D, tDAt_{DA}.
  • Dimensionless quantities do not depend on the system of units. tDt_D and CDC_D calculated in metric units and in oilfield units are the same, and this is how we check the constants and the conversions.
  • A line source (a well of zero radius) passes through the wall of the well only the share e−1/(4tD)\e^{-1/(4t_D)} of the rate: at tD=1t_D = 1 this is 78%, and at tD=25t_D = 25 it is 99%. A few seconds after start-up it already replaces the exact solution. In fact, the first minutes of the record are set by wellbore storage.
  • We can add the skin to the solution, or replace it by an effective wellbore radius, rw′=rwe−Sr_w' = r_w\e^{-S}. At late times the two are the same. At the beginning, a negative skin is described correctly only by the “enlarged” well. The semilog straight line starts when tDe2St_D\e^{2S} reaches about 100.
  • The radius of investigation, ri=4ηtr_i = \sqrt{4\eta t}, is a conventional boundary. There the rate of pressure decline is just passing through its maximum (the pressure falls fastest right at the well). 85% of the volume withdrawn from the reservoir comes from inside rir_i, and 95% comes from inside 1.33 ri1.33\,r_i. An accurate gauge in a neighbouring well notices a response about twice as far away.
  • The radius of drainage, rd=0.75 rir_d = 0.75\,r_i, is the radius of steady-state flow with the same pressure drop. While it grows, the productivity index falls. After pseudo-steady state is reached, we calculate productivity with respect to the average reservoir pressure.
Key relationships
tD=ktϕμctrw2,pD=2πkh ΔpqBμ,CD=C2πϕcthrw2t_D = \dfrac{kt}{\phi\mu c_t r_w^2},\quad p_D = \dfrac{2\pi kh\,\Delta p}{qB\mu},\quad C_D = \dfrac{C}{2\pi\phi c_t h r_w^2}

dimensionless time, pressure and wellbore storage coefficient (SI)

q(r,t)=q e−r2/(4ηt)q(r, t) = q\,\e^{-r^2/(4\eta t)}

flow rate through a circle of radius rr in the line-source solution

ri=4ηt,rd=4ηt/γ=0.75 rir_i = \sqrt{4\eta t},\qquad r_d = \sqrt{4\eta t/\gamma} = 0.75\,r_i

radius of investigation and radius of drainage; η=k/(ϕμct)\eta = k/(\phi\mu c_t), γ=1.781\gamma = 1.781

V(r)V=1−e−X+X E1(X),X=r24ηt\dfrac{V(r)}{V} = 1 - \e^{-X} + X\,E_1(X),\quad X = \dfrac{r^2}{4\eta t}

share of the withdrawn volume supplied by the reservoir inside radius rr

Jt=2πkhBμ [ln⁡(rd/rw)+S]J_t = \dfrac{2\pi kh}{B\mu\,[\ln(r_d/r_w) + S]}

transient productivity index (SI; in metric oilfield units 2π2\pi is replaced by 0.536)

Common pitfalls
  • Putting oilfield constants (2.637·10⁻⁴, 141.2, 0.8936) into metric data, or the other way round. The check: tDt_D and CDC_D in the two systems must be the same.
  • Adding a large negative skin to the finite-radius solution in the first moments. The result is a “rise” of pressure during production.
  • Taking the radius of investigation as a sharp boundary beyond which the pressure has not yet changed.
  • Mixing up the radius of drainage with the radius of investigation, or with the radius of the drainage area rer_e.
  • Taking the productivity from a short flow period as the stabilised one. It is too high while the radius of drainage is still growing.

After this lesson you can

  • list the dimensionless groups of well testing, and convert dimensionless solutions to metric and oilfield units with checked constants
  • explain how a finite-radius well differs from a line source (a well replaced by a line of zero radius), and use a numerical criterion to decide when a line source is good enough: at the wall of the well, away from it, and with a negative skin
  • put the skin into a dimensionless solution, either as an added term or as an effective wellbore radius, and estimate when a zone of changed permeability of finite size behaves like a thin skin
  • calculate the radius of investigation by several definitions, and explain why they give different numbers
  • tell the radius of drainage from the radius of investigation, and estimate the transient productivity index (the productivity index while the pressure is still changing)

Dimensionless groups of the well

The problem of a well in a homogeneous reservoir contains about ten dimensional quantities (quantities with units): permeability, thickness, porosity, viscosity, compressibility, well radius, rate, formation volume factor, wellbore volume and the distances to the boundaries. Dimensionless variables reduce them to a few groups (the dimensionless form of the equation). We measure distances in well radii, pressure in “units” of the radial-flow pressure drop, and time in units of rw2/ηr_w^2/\eta. In that time the disturbance travels a distance of about one well radius. For an ordinary well this is a fraction of a second.

Each new feature of the well or the reservoir adds one group to the problem. The skin adds the number SS, the wellbore volume adds CDC_D, and a boundary adds the dimensionless distance to it. The solution becomes a function of tDt_D and these parameters, pD=f(tD; S, CD, reD,… )p_D = f(t_D;\,S,\,C_D,\,r_{eD},\dots). Two wells with the same groups have the same curve pD(tD)p_D(t_D), only on different pressure and time scales. Type curves (Type-curve matching) are built on this.

Dimensionless groups of well testing
Group
rD=r/rwr_D = r/r_w
What it compares
the distance compared with the well radius
Typical values
1 at the wall; 10310^3–10510^5 at the boundaries
Group
tD=ηt/rw2t_D = \eta t/r_w^2
What it compares
the time compared with the time the disturbance needs to cross the well radius
Typical values
from tens to millions per hour
Group
pD=Δp⋅2πkh/(qBμ)p_D = \Delta p\cdot 2\pi kh/(qB\mu)
What it compares
the pressure drop compared with the “unit” of radial flow
Typical values
5–20 in radial flow
Group
SS
What it compares
the extra pressure drop at the wellbore, in the same “units”
Typical values
from −5 to +20 and more
Group
CD=C/(2πϕcthrw2)C_D = C/(2\pi\phi c_thr_w^2)
What it compares
the storage capacity of the wellbore compared with that of the reservoir around the wellbore
Typical values
from single digits to 10410^4 and more
Group
reD=re/rwr_{eD} = r_e/r_w, LD=L/rwL_D = L/r_w
What it compares
the size of the area and the distances to the boundaries
Typical values
10310^3–10510^5
Group
tDA=ηt/At_{DA} = \eta t/A
What it compares
the time compared with the time needed to cover the area AA
Typical values
0.1: the start of pseudo-steady state in a circle

η=k/(ϕμct)\eta = k/(\phi\mu c_t) is the hydraulic diffusivity (how fast pressure spreads through the rock), and Δp=pi−p\Delta p = p_i - p. For type curves we combine the groups: tD/CDt_D/C_D and CDe2SC_D\e^{2S} (Type-curve matching), and tD/LD2=ηt/L2t_D/L_D^2 = \eta t/L^2 for boundaries (Semi-infinite systems: theory and test analysis).

Constants in three systems of units

To go from a dimensionless solution back to quantities with units, we do two things. We multiply the dimensionless time by the characteristic time ϕμctrw2/k\phi\mu c_tr_w^2/k, and we multiply the dimensionless pressure by the pressure “unit”. In metric oilfield units and in oilfield units, these scales contain constants: conversion factors collected into a single number (formula constants).

Conversion of a dimensionless solution to pressure drop and time
Δp=qBμ2πkh pD,t=ϕμctrw2k tD\Delta p = \frac{qB\mu}{2\pi kh}\,p_D,\qquad t = \frac{\phi\mu c_t r_w^2}{k}\,t_D
where:
  • Δp\Delta ppressure decline pi−pp_i - p at the point considered, Pa
  • tttime since start-up of the well, s
  • pD, tDp_D,\ t_Ddimensionless pressure and time read from the solution or the type curve, —
  • q, Bq,\ Brate at standard conditions and formation volume factor; qBqB is the rate at reservoir conditions, m³/s, m³/m³
  • k, h, μk,\ h,\ \mupermeability, reservoir thickness, viscosity, m², m, Pa·s
  • ϕ, ct, rw\phi,\ c_t,\ r_wporosity, total compressibility, well radius, —, 1/Pa, m

Units: SI

Holds when
  • The conditions of the diffusivity equation hold: the fluid is single-phase and slightly compressible, and the properties of the reservoir and the fluid are constant (Diffusivity equation).
  • Δp\Delta p is positive for production. For an injection well the sign is opposite.

Both formulas are the definitions of pDp_D and tDt_D, solved for the quantities with units. Everything that makes one well differ from another with the same dimensionless parameters sits in two scales: the pressure “unit” qBμ/(2πkh)qB\mu/(2\pi kh) and the characteristic time ϕμctrw2/k\phi\mu c_tr_w^2/k.

In other unit systems (2)
Metric oilfield units
Δp=1.866 qBμkh pD,t=ϕμctrw23.553⋅10−3 k tD\Delta p = 1.866\,\frac{qB\mu}{kh}\,p_D,\qquad t = \frac{\phi\mu c_t r_w^2}{3.553\cdot10^{-3}\,k}\,t_D

qq in m³/d at standard conditions, μ\mu in mPa·s, kk in mD, hh and rwr_w in m, ctc_t in 1/MPa; Δp\Delta p in MPa, tt in h.

1.866=1/(2π⋅0.0853)1.866 = 1/(2\pi\cdot0.0853), where 0.08530.0853 is the constant of Darcy's law in these units, and 3.553⋅10−3=0.9869⋅10−15⋅3600/(10−3⋅10−6)3.553\cdot10^{-3} = 0.9869\cdot10^{-15}\cdot3600/(10^{-3}\cdot10^{-6}).

Oilfield units
Δp=141.2 qBμkh pD,t=ϕμctrw22.637⋅10−4 k tD\Delta p = 141.2\,\frac{qB\mu}{kh}\,p_D,\qquad t = \frac{\phi\mu c_t r_w^2}{2.637\cdot10^{-4}\,k}\,t_D

qq in STB/d (stock-tank barrels per day), μ\mu in cP (centipoise), kk in mD, hh and rwr_w in ft, ctc_t in 1/psi; Δp\Delta p in psi, tt in h.

141.2=1/(2π⋅1.127⋅10−3)141.2 = 1/(2\pi\cdot1.127\cdot10^{-3}), where 1.127⋅10−31.127\cdot10^{-3} is the constant of Darcy's law in oilfield units. 2.637⋅10−42.637\cdot10^{-4} is the same kind of conversion, for millidarcy, centipoise, psi, feet and hours.

The constant aa of the dimensionless groups and test formulas in three systems of units
Quantity
tDt_D
Formula
a kt/(ϕμctrw2)a\,kt/(\phi\mu c_tr_w^2)
SI
1
Metric oilfield
3.553⋅10−33.553\cdot10^{-3}
Oilfield
2.637⋅10−42.637\cdot10^{-4}
Quantity
pDp_D
Formula
a kh Δp/(qBμ)a\,kh\,\Delta p/(qB\mu)
SI
2π2\pi
Metric oilfield
1/1.8661/1.866
Oilfield
1/141.21/141.2
Quantity
CDC_D
Formula
a C/(ϕcthrw2)a\,C/(\phi c_thr_w^2)
SI
1/(2π)1/(2\pi)
Metric oilfield
1/(2π)1/(2\pi)
Oilfield
0.89360.8936
Quantity
tD/CDt_D/C_D
Formula
a kh t/(μC)a\,kh\,t/(\mu C)
SI
2π2\pi
Metric oilfield
1/44.81/44.8
Oilfield
2.951⋅10−42.951\cdot10^{-4}
Quantity
rir_i
Formula
akt/(ϕμct)a\sqrt{kt/(\phi\mu c_t)}
SI
2
Metric oilfield
0.1190.119
Oilfield
0.03250.0325
Quantity
rdr_d
Formula
akt/(ϕμct)a\sqrt{kt/(\phi\mu c_t)}
SI
1.4991.499
Metric oilfield
0.08930.0893
Oilfield
0.02430.0243
Quantity
mm
Formula
a qBμ/(kh)a\,qB\mu/(kh)
SI
0.18320.1832
Metric oilfield
2.1492.149
Oilfield
162.6162.6
Quantity
mem_e
Formula
a qBμ/(kh)a\,qB\mu/(kh)
SI
1/(4π)1/(4\pi)
Metric oilfield
0.9330.933
Oilfield
70.670.6

Metric oilfield units: kk in mD, hh and rr in m, tt in h, μ\mu in mPa·s, ctc_t in 1/MPa, pressure in MPa, qq in m³/d at standard conditions, CC in m³/MPa. Oilfield units: kk in mD, hh and rr in ft, tt in h, μ\mu in cP, ctc_t in 1/psi, pressure in psi, qq in STB/d, CC in bbl/psi. Here mm is the slope of the semilog straight line per decimal cycle (Pressure drawdown analysis), mem_e is the level of the derivative plateau (the flat part of the pressure derivative curve; the derivative is the slope of the pressure against the logarithm of time; Diagnosis with the pressure derivative), and rdr_d is the radius of drainage (see the section below). tDAt_{DA} has the same constant as tDt_D, with the area AA in place of rw2r_w^2 (in oilfield units the area is in square feet; 1 acre = 43,560 ft²). All constants are recalculated from the exact definitions: 1 ft = 0.3048 m, 1 bbl = 0.158987 m³, 1 psi = 6894.757 Pa, 1 mD = 0.9869233⋅10−150.9869233\cdot10^{-15} m², 1 cP = 1 mPa·s.

Worked exampleA report in oilfield units: checking the dimensionless groups
Given (assumed data)
Well and reservoir (from a service company's report)
qq = 503 STB/d; BB = 1.25; μ\mu = 1.1 cP; kk = 40 mD; hh = 32.8 ft; ϕ\phi = 0.19
Compressibility, radius, wellbore, skin
ct=1.10⋅10−5c_t = 1.10\cdot10^{-5} psi⁻¹; rwr_w = 0.328 ft; C=5.2⋅10−4C = 5.2\cdot10^{-4} bbl/psi; SS = 2
Conversions
1 ft = 0.3048 m; 1/psi = 145.04 1/MPa; 1 bbl/psi = 23.06 m³/MPa
Solution
  1. In oilfield units, the dimensionless time per hour is found like this: ϕμctrw2=0.19⋅1.1⋅1.10⋅10−5⋅0.3282=2.4734⋅10−7\phi\mu c_tr_w^2 = 0.19\cdot1.1\cdot1.10\cdot10^{-5}\cdot0.328^2 = 2.4734\cdot10^{-7}, and tD=2.637⋅10−4⋅40/(2.4734⋅10−7)=42,646t_D = 2.637\cdot10^{-4}\cdot40/(2.4734\cdot10^{-7}) = 42{,}646.
  2. The dimensionless wellbore storage coefficient is CD=0.8936⋅5.2⋅10−4/(0.19⋅1.10⋅10−5⋅32.8⋅0.3282)=63.0C_D = 0.8936\cdot5.2\cdot10^{-4}/(0.19\cdot1.10\cdot10^{-5}\cdot32.8\cdot0.328^2) = 63.0.
  3. Now the same data in metric units: ct=1.5954⋅10−3c_t = 1.5954\cdot10^{-3} MPa⁻¹, rw=0.09997r_w = 0.09997 m, h=9.997h = 9.997 m, and C=5.2⋅10−4⋅23.06=0.01199C = 5.2\cdot10^{-4}\cdot23.06 = 0.01199 m³/MPa.
  4. The metric calculation gives tD=3.553⋅10−3⋅40/(0.19⋅1.1⋅1.5954⋅10−3⋅0.099972)=42,648t_D = 3.553\cdot10^{-3}\cdot40/(0.19\cdot1.1\cdot1.5954\cdot10^{-3}\cdot0.09997^2) = 42{,}648 per hour and CD=0.01199/(2π⋅0.19⋅1.5954⋅10−3⋅9.997⋅0.099972)=63.0C_D = 0.01199/(2\pi\cdot0.19\cdot1.5954\cdot10^{-3}\cdot9.997\cdot0.09997^2) = 63.0.
  5. By the rule tD≈(60+3.5S) CDt_D \approx (60 + 3.5S)\,C_D (Wellbore storage), wellbore storage ends at tD=67⋅63.0=4221t_D = 67\cdot63.0 = 4221. That is 4221/42,648=0.09904221/42{,}648 = 0.0990 h, or about 5.9 min after start-up.
Answer: In both systems tD≈42,648t_D \approx 42{,}648 per hour and CD≈63.0C_D \approx 63.0. The semilog straight line can start about 5.9 min after start-up.

What it means. The check is that the dimensionless groups agree to the third or fourth significant digit. A lost or extra conversion factor would give a difference of several times. The small difference that remains comes from rounding the report data (0.328 ft is 0.09997 m). The conversion of bbl/psi to m³/MPa (the factor 23.06) is a frequent source of errors when the wellbore storage coefficient is carried over from foreign reports. The data in this example are assumed for illustration.

The finite-radius well and the line source

The solutions represent a well in two ways. The line source is a line of zero radius through which the rate is withdrawn. Its pressure is written with the exponential integral (a special mathematical function; Line-source solution and the pressure function). The finite-radius well (finite wellbore radius solution, cylindrical source) is a cylinder of radius rwr_w with the same rate specified on its wall. Its solution is written with Bessel functions (another family of special functions). The lesson on the line source compares the two solutions at the wall of the well. Here we look at why they differ, and where exactly.

The reason can be seen in the flow rate. In the line-source solution, only a part of the well's rate passes through a circle of radius rr, not the whole rate:

Flow rate through a circle in the line-source solution
q(r,t)q=exp⁡ ⁣(−r24ηt)=exp⁡ ⁣(−rD24tD)\frac{q(r, t)}{q} = \exp\!\left(-\frac{r^2}{4\eta t}\right) = \exp\!\left(-\frac{r_D^2}{4t_D}\right)
where:
  • q(r,t)q(r, t)flow rate of fluid through a cylindrical surface of radius rr at time tt, reduced to standard conditions, m³/s
  • qqwell rate at standard conditions, m³/s
  • η\etahydraulic diffusivity k/(ϕμct)k/(\phi\mu c_t), m²/s
  • rD, tDr_D,\ t_Ddimensionless distance and time, —

Units: no units (a ratio of rates)

Holds when
  • This is the line-source solution: the reservoir is infinite and homogeneous, and the rate is constant from start-up (the derivation is in the advanced section).

The rest of the rate is supplied by the fluid and rock expanding inside the circle. For a circle the size of the well radius, this means that the line-source model takes part of the rate “from the wellbore”, that is, from rock that is not there. At tD=1t_D = 1 only 78% of the rate passes through the wall. At tD=5t_D = 5 it is 95%, at tD=25t_D = 25 it is 99%, and at tD=100t_D = 100 it is 99.75%. This gives the condition tD>25t_D > 25. After that point, the two formulations differ by less than one per cent of the rate.

The exact solution for a finite-radius well in Laplace space (the result of a mathematical transform of the time variable) is written for any point of the reservoir:

Finite-radius well: pressure in the reservoir in Laplace space
pˉD(rD,s)=K0 ⁣(rDs)s3/2 K1 ⁣(s),rD≥1\bar p_D(r_D, s) = \frac{K_0\!\left(r_D\sqrt{s}\right)}{s^{3/2}\,K_1\!\left(\sqrt{s}\right)},\qquad r_D \ge 1
where:
  • pˉD(rD,s)\bar p_D(r_D, s)Laplace transform of the dimensionless pressure decline at the distance rDr_D, —
  • ssvariable of the Laplace transform with respect to tDt_D, —
  • K0, K1K_0,\ K_1modified Bessel functions of the second kind of order zero and one, —

Units: no units

Holds when
  • The reservoir is infinite, the rate at the wall rD=1r_D = 1 is constant, and there is no skin and no wellbore storage. We return to the function of time numerically (Stehfest algorithm).

At rD=1r_D = 1 this is the solution at the wall given in the lesson on the line source. For the line source in the same variables, pˉD=K0(rDs)/s\bar p_D = K_0(r_D\sqrt s)/s. The factor 1/(s K1(s))1/(\sqrt s\,K_1(\sqrt s)) tends to one at small ss, that is, at large times. Then the two solutions coincide.

Dimensionless pressure near the well: finite-radius well and line source12510200123Dimensionless distance rDDimensionless pressure pD100101solid — finite radiusdashed — line sourcenumbers — dimensionless time

Graph of dimensionless pressure, from 0 to 3, against dimensionless distance, from 1 to 30, on a logarithmic scale. There are three pairs of curves, for dimensionless times 1, 10 and 100. For time 1, the solid curve starts at 0.80 at the wall and the dashed one at 0.52. Both fall to zero by five radii. For time 10, the solid curve starts at 1.65 and the dashed one at 1.57. Both decline to zero by 15–20 radii. For time 100, the curves start at 2.72 and 2.71 and almost coincide. They decline to 0.1 at 20 radii.

CalculatedCalculated dimensionless pressure decline near the well at tDt_D = 1, 10 and 100: the finite-radius well (solid lines) and the line source (dashed). The distance scale is logarithmic, from the wall of the well (rD=1r_D = 1) to 30 well radii. The difference is large only in the first moments and right at the well.
Dimensionless pressure near the well: finite radius and line source
rDr_D
1
tD=10t_D = 10: exact
1.651
line
1.568
tD=100t_D = 100: exact
2.723
line
2.708
rDr_D
2
tD=10t_D = 10: exact
0.975
line
0.911
tD=100t_D = 100: exact
2.032
line
2.019
rDr_D
5
tD=10t_D = 10: exact
0.244
line
0.216
tD=100t_D = 100: exact
1.138
line
1.128
rDr_D
10
tD=10t_D = 10: exact
0.016
line
0.012
tD=100t_D = 100: exact
0.529
line
0.522

“Exact” is the finite-radius solution, and “line” is the line source, 12E1(rD2/(4tD))\tfrac12E_1(r_D^2/(4t_D)). At tD=100t_D = 100 the difference over the whole near zone is about 0.01: from 0.015 at the wall to 0.007 at ten radii. It decreases more slowly than 1/tD1/t_D: at the wall, from tDt_D = 10 to 100, it falls by almost a factor of six.

Skin in the dimensionless solution: a term or an effective radius

Skin is an additional pressure drop in a thin zone at the wellbore (definition of skin). The dimensionless solution can account for it in two ways. We can add it to the pressure at the wall. Or we can replace the well by another one, without skin but with an effective wellbore radius rw′=rwe−Sr_w' = r_w\e^{-S} (effective radius).

Two ways of accounting for skin in the solution for a well
pwD(tD)=pD(tD)+SorpwD(tD)=pD ⁣(tD e2S)p_{wD}(t_D) = p_D(t_D) + S\qquad\text{or}\qquad p_{wD}(t_D) = p_D\!\left(t_D\,\e^{2S}\right)
where:
  • pwDp_{wD}dimensionless decline of the bottomhole pressure of a well with skin, —
  • pD(tD)p_D(t_D)solution for a finite-radius well without skin, at the wall, —
  • SSskin factor, —
  • e2S\e^{2S}the ratio (rw/rw′)2(r_w/r_w')^2: the dimensionless time of a well with the effective radius is tDe2St_D\e^{2S}, —

Units: no units

Holds when
  • The first form is the skin of an infinitely thin zone that follows the rate instantly.
  • The second form is a well without skin, of radius rw′=rwe−Sr_w' = r_w\e^{-S}, in the same reservoir. The pressure is still referred to the kk and hh of the reservoir.
  • Wellbore storage is not included. It can be added to either form (Wellbore storage).

In the logarithmic approximation the two forms are the same: 12[ln⁡(tDe2S)+0.809]=12(ln⁡tD+0.809)+S\tfrac12[\ln(t_D\e^{2S}) + 0.809] = \tfrac12(\ln t_D + 0.809) + S. They differ at the beginning. An added negative skin gives a negative pwDp_{wD} at small tDt_D, which is a “rise” of pressure during production. A well with an enlarged radius stays physical (it behaves like a real well): its pressure comes to the same straight line when tDe2St_D\e^{2S} becomes larger than 25–100.

A practical consequence follows for treated wells (wells whose near-wellbore zone has been stimulated). The semilog straight line starts not at tD≈100t_D \approx 100 but at tD≈100 e−2St_D \approx 100\,\e^{-2S}: at about 5500 for S=−2S = -2, and at about 40,000 for S=−3S = -3. For a damaged well (S>0S > 0) the effective radius is tiny, so the condition is met at once. But a real damaged zone has a size and its own transient (see the advanced section).

Worked exampleWhen the semilog straight line starts in a treated well
Given (assumed data)
The lesson's well after an acid treatment
SS = −2; rwr_w = 0.1 m; η\eta = 425 m²/h; per hour tDt_D = 42,500
Wellbore
CC = 0.012 m³/MPa, CDC_D = 62.8
Solution
  1. The effective radius is rw′=0.1⋅e2=0.739r_w' = 0.1\cdot\e^{2} = 0.739 m.
  2. The condition tDe2S>100t_D\e^{2S} > 100 is the same as ri>20 rw′r_i > 20\,r_w'. So t>100 rw′2/η=100⋅0.7392/425=0.1285t > 100\,r_w'^2/\eta = 100\cdot0.739^2/425 = 0.1285 h, which is about 7.7 min.
  3. By the rule (60+3.5S) CD(60 + 3.5S)\,C_D, wellbore storage lasts until tD=53⋅62.8=3328t_D = 53\cdot62.8 = 3328, that is, 4.7 min. This rule is a guide for CDe2S>103C_D\e^{2S} > 10^3 (Wellbore storage). Here, however, CDe2S=1.15C_D\e^{2S} = 1.15. The wellbore is small compared with the storage of the reservoir around the “enlarged” well, so the rule has been applied outside its range.
  4. Check with the solution for a well of radius rw′r_w'. After 2 min (tDt_D = 1417, tDe−4t_D\e^{-4} = 25.9), pwD=2.0793p_{wD} = 2.0793, while the semilog formula 12(ln⁡tD+0.809)+S\tfrac12(\ln t_D + 0.809) + S gives 2.0326, which is less by 2.2%. After 10 min the two values are 2.8500 and 2.8373, a difference of 0.45%.
  5. Now include both effects: the same well of radius rw′r_w', with wellbore storage, CDe2S=1.15C_D\e^{2S} = 1.15. Then pwDp_{wD} is lower than the semilog value by 0.9% after 4.7 min and by 0.56% after 7.7 min. Wellbore storage and the size of the well act in opposite directions here, on the same scale. But the conclusion is the same: before 7.7 min the straight line is no more accurate than half a per cent.
Answer: The semilog straight line of this well starts after about 7.7 min. This is later than wellbore storage ends by the usual rule (about 4.7 min).

What it means. In a treated well, the start of the straight line can be set not by the wellbore but by the “size” of the well. The more negative the skin, the longer the pressure remembers the near zone. The effective radius is a simplification (the treated zone is treated as if it were infinitely permeable). A zone of finite permeability comes to the same straight line in a similar time (see the advanced section). In a well with a hydraulic fracture, the early flow is not radial at all. It is linear towards the fracture, and the effective radius describes only the late radial flow (Inflow to a hydraulically fractured well). The data in this example are assumed for illustration.

The radius of investigation: how far a test “sees”

The disturbance has no sharp front. According to the diffusivity equation, the pressure starts to change at once throughout the reservoir. Far away it changes by a vanishingly small amount. So the question “how far does a test see?” has several answers, and each answers a different question. The radius of investigation ri=4ηtr_i = \sqrt{4\eta t}, used in practice (planning of tests), has a simple physical meaning. At a point at this distance, the rate of pressure decline is passing through its maximum at the given moment: before that it was growing, and afterwards it will fall.

Rate of pressure decline at a point in the reservoir
∂ Δp∂t=qBμ4πkh⋅1t exp⁡ ⁣(−r24ηt)\frac{\partial\,\Delta p}{\partial t} = \frac{qB\mu}{4\pi kh}\cdot\frac1t\,\exp\!\left(-\frac{r^2}{4\eta t}\right)
where:
  • Δp\Delta ppressure decline pi−pp_i - p at the distance rr from the well, Pa
  • tttime since start-up, s
  • q, B, μ, k, hq,\ B,\ \mu,\ k,\ hrate at standard conditions, formation volume factor, viscosity, permeability, thickness, m³/s, m³/m³, Pa·s, m², m
  • η\etahydraulic diffusivity k/(ϕμct)k/(\phi\mu c_t), m²/s

Units: SI

Holds when
  • This is the line-source solution: the reservoir is infinite, and the rate is constant.

At a point at the distance rr, the rate of pressure decline first grows and then falls. Its maximum is exactly at t=r2/(4η)t = r^2/(4\eta), that is, when r=rir = r_i. So rir_i is the place where the drawdown cone (the region where the pressure has dropped) is deepening, right now, at the highest rate for that point. It is a moving “front” of the disturbance (overall, the pressure falls fastest right at the well). The pressure decline there already equals 0.110.11 of a “unit” qBμ/(2πkh)qB\mu/(2\pi kh). After that it continues, only more slowly.

The second question is where the withdrawn fluid came from. It is supplied by the fluid and rock expanding throughout the drawdown cone. The share supplied inside radius rr is written with the same function E1E_1:

Share of the withdrawn volume supplied by the reservoir inside radius r
V(r)V=1−e−X+X E1(X),X=r24ηt=(rri)2\frac{V(r)}{V} = 1 - \e^{-X} + X\,E_1(X),\qquad X = \frac{r^2}{4\eta t} = \left(\frac{r}{r_i}\right)^2
where:
  • V(r)V(r)volume of fluid (at reservoir conditions) supplied by elastic expansion inside a circle of radius rr, m³
  • VVthe whole withdrawn volume qBtqBt, m³
  • E1(X)E_1(X)exponential integral, —
  • rir_iradius of investigation 4ηt\sqrt{4\eta t}, m

Units: no units

Holds when
  • This is the line-source solution: the reservoir is infinite, and the rate is constant from start-up (the derivation is in the advanced section).

Inside the radius of drainage, 0.75 ri0.75\,r_i, 71% of the volume is supplied. Inside rir_i it is 85%, and inside 1.33 ri1.33\,r_i it is 95%. The pressure drop is concentrated at the well, but the volume comes from far away. The area of a ring grows with the radius, and a small pressure decline over a large area yields a lot of fluid.

The third question is where a gauge will notice the response. The answer depends on the rate and on the gauge resolution. A pressure decline δp\delta p is reached at the distance where meE1(X)=δpm_eE_1(X) = \delta p, with me=qBμ/(4πkh)m_e = qB\mu/(4\pi kh) the level of the derivative plateau (Diagnosis with the pressure derivative). The lesson on the line source shows how this is used in interference testing. The fourth question is at what distance a boundary already changes the pressure in the well itself. We answer it with the pressure derivative: by how many per cent it rises above the plateau (the derivative step at a fault).

Radii that answer different questions, in fractions of the radius of investigation
Criterion
The rate of pressure decline passes its maximum
Radius
rir_i
Remark
the pressure decline there is 0.110.11 of a “unit” qBμ/(2πkh)qB\mu/(2\pi kh)
Criterion
Steady-state flow with the same pressure drop
Radius
0.75 ri0.75\,r_i
Remark
the radius of drainage (the section below)
Criterion
Half of the withdrawn volume comes from within
Radius
0.52 ri0.52\,r_i
Remark
almost the whole pressure drop is inside this circle
Criterion
85% of the volume comes from within
Radius
rir_i
Remark
the share inside rir_i is 85.2%
Criterion
95% of the volume comes from within
Radius
1.33 ri1.33\,r_i
Remark
99% is inside 1.75 ri1.75\,r_i
Criterion
The pressure decline is 1% of mem_e
Radius
1.79 ri1.79\,r_i
Remark
a gauge in a neighbouring well; depends on the rate
Criterion
A fault raises the derivative by 1%
Radius
1.07 ri1.07\,r_i
Remark
by 10% — a fault not farther than 0.76 ri0.76\,r_i
Criterion
A closed circle raises the derivative by 1%
Radius
1.32 ri1.32\,r_i
Remark
the radius of the circle; by 10% — 1.06 ri1.06\,r_i

Calculated from the line-source solution; for a closed circle with the well at the centre, from the exact solution. The ratios do not depend on the properties of the reservoir, because everything is expressed through ri=4ηtr_i = \sqrt{4\eta t}. A boundary begins to show on the derivative at about the time when the radius of investigation reaches it. The influence must reach the boundary and return, and a fault at the distance rir_i raises the derivative by only about 2%.

Share of the pressure drop and share of the withdrawn volume against distance one day after start-up01002003004005000.000.250.500.751.00Distance from the well r, mShare151 m202 m270 mshare of withdrawn volumeshare of pressure drop

Graph in ordinary (not logarithmic) coordinates. The horizontal axis is the distance from the well, from 0 to 500 metres. The vertical axis is the share, from 0 to 1. The orange curve, the share of the pressure drop, starts at one at the wall of the well and falls steeply: 0.69 at one metre, 0.37 at 10 metres, 0.25 at 25 metres, 0.07 at 100 metres, and almost zero after 250 metres. The teal curve, the share of the volume, rises from zero: 0.2 at 50 metres, 0.5 at 104 metres, 0.71 at 151 metres, 0.85 at 202 metres, 0.95 at 270 metres, and then approaches one. Three points are marked on the teal curve, at 151, 202 and 270 metres.

CalculatedCalculation for the lesson's well one day after start-up (rir_i = 202 m). The orange curve is the share of the pressure drop: the pressure decline at the distance rr divided by the decline at the wall of the well (without skin). The teal curve is the share of the withdrawn volume supplied by the reservoir inside radius rr. The points mark the radius of drainage, the radius of investigation, and the radius inside which 95% of the volume is supplied.
Worked exampleHow far a one-day flow period “sees”: four answers
Given (assumed data)
The lesson's well
qq = 80 m³/d; BB = 1.25; μ\mu = 1.1 mPa·s; kk = 40 mD; hh = 10 m; ϕ\phi = 0.19; ct=1.6⋅10−3c_t = 1.6\cdot10^{-3} MPa⁻¹; η\eta = 425 m²/h
Time since start-up
24 h; there are no boundaries nearby, so the reservoir behaves as an infinite one
Gauge in a neighbouring well
reliably detects a pressure change of 0.5 kPa (0.0005 MPa)
Solution
  1. The radius of investigation is ri=4⋅425⋅24=202r_i = \sqrt{4\cdot425\cdot24} = 202 m. The radius of drainage is 0.749⋅202=1510.749\cdot202 = 151 m.
  2. Where the fluid comes from: half of the withdrawn volume is supplied inside 0.517 ri=1040.517\,r_i = 104 m, and 95% inside 1.335 ri=2701.335\,r_i = 270 m.
  3. The neighbouring well: me=0.933⋅80⋅1.25⋅1.1/(40⋅10)=0.2566m_e = 0.933\cdot80\cdot1.25\cdot1.1/(40\cdot10) = 0.2566 MPa. We need E1(X)=0.0005/0.2566=0.00195E_1(X) = 0.0005/0.2566 = 0.00195, so X=4.55X = 4.55 and r=X ri=431r = \sqrt{X}\,r_i = 431 m.
  4. The boundary: by the end of the day a fault will raise the derivative by 10% if it is closer than 0.759 ri=1530.759\,r_i = 153 m, and by at least 1% if it is closer than 1.073 ri=2171.073\,r_i = 217 m.
Answer: In a day the test “reached” anywhere from 151 to 431 m, depending on what we count. The radius of drainage is 151 m and the radius of investigation is 202 m. 95% of the volume comes from within 270 m. The response in the neighbouring well extends to 431 m. A fault is noticeable on the derivative up to 217 m.

What it means. For productivity and inflow formulas we need the radius of drainage. For the question “what volume did the oil come from?” we need the radii of the volume shares. For interference testing we need the radius at which the response exceeds the gauge resolution. For finding boundaries we need the derivative criterion. The last one is slightly wider than rir_i at the 1% level and narrower at the 10% level. So we can recognise a fault confidently on a record only when it is noticeably closer than the radius of investigation. The data in this example are assumed for illustration.

The radius of drainage and the transient productivity

Near the well, where the disturbance arrived long ago, the pressure profile is almost steady-state. The flow rate through the circles hardly changes with the radius, and the pressure grows with distance as the logarithm, as in the Dupuit equation (quasi-steady-state profile). Let us continue this logarithmic straight line out to the initial pressure pip_i. The radius at which the line reaches pip_i is called the radius of drainage. The Dupuit equation with re=rdr_e = r_d gives the same bottomhole pressure as transient flow. This is not the radius of the drainage area rer_e, which in Russian-language practice is sometimes also called the radius of drainage or the radius of the supply contour. rer_e is set by the boundaries, while rdr_d grows with time.

The radius of drainage in transient flow
rd=4ηtγ=0.749 ri,pi−pwf=qBμ2πkh(ln⁡rdrw+S)r_d = \sqrt{\frac{4\eta t}{\gamma}} = 0.749\,r_i,\qquad p_i - p_{wf} = \frac{qB\mu}{2\pi kh}\left(\ln\frac{r_d}{r_w} + S\right)
where:
  • rdr_dradius of drainage at time tt, m
  • γ\gammae0.5772=1.781\e^{0.5772} = 1.781, —
  • rir_iradius of investigation 4ηt\sqrt{4\eta t}, m
  • pi, pwfp_i,\ p_{wf}initial reservoir pressure and bottomhole flowing pressure, Pa
  • q, B, μ, k, h, Sq,\ B,\ \mu,\ k,\ h,\ Srate at standard conditions, formation volume factor, viscosity, permeability, thickness, skin, m³/s, m³/m³, Pa·s, m², m, —

Units: SI; the logarithm is natural

Holds when
  • The rate is constant, and the reservoir is infinite and homogeneous.
  • tD>25t_D > 25, so the logarithmic approximation is valid at the wall of the well.

The second formula is the same pressure function, 12(ln⁡tD+0.809)+S\tfrac12(\ln t_D + 0.809) + S, rewritten as the Dupuit equation. The radius of drainage grows as the square root of time, and it is always three quarters of the radius of investigation. Beyond it, the pressure already differs from the logarithmic straight line. That line “rests” on pip_i at rdr_d, while the real profile approaches pip_i smoothly farther out.

In other unit systems (2)
Metric oilfield units
rd=0.0893k tϕμctr_d = 0.0893\sqrt{\frac{k\,t}{\phi\mu c_t}}

rdr_d in m, kk in mD, tt in h, μ\mu in mPa·s, ctc_t in 1/MPa.

0.0893=4⋅3.553⋅10−3/1.7810.0893 = \sqrt{4\cdot3.553\cdot10^{-3}/1.781}.

Oilfield units
rd=0.0243k tϕμctr_d = 0.0243\sqrt{\frac{k\,t}{\phi\mu c_t}}

rdr_d in ft, kk in mD, tt in h, μ\mu in cP, ctc_t in 1/psi.

0.0243=4⋅2.637⋅10−4/1.7810.0243 = \sqrt{4\cdot2.637\cdot10^{-4}/1.781}.

In transient flow, the ratio of the rate to the drawdown is called the transient productivity index. It is the same productivity formula as for steady-state flow, only with a growing radius of drainage:

Transient productivity index
Jt=qpi−pwf(t)=2πkhBμ[ln⁡(rd/rw)+S]J_t = \frac{q}{p_i - p_{wf}(t)} = \frac{2\pi kh}{B\mu\left[\ln(r_d/r_w) + S\right]}
where:
  • JtJ_tproductivity index at time tt, with respect to the initial pressure, m³/(s·Pa)
  • pwf(t)p_{wf}(t)bottomhole flowing pressure at time tt at a constant rate, Pa
  • rdr_dradius of drainage at time tt, m
  • k, h, B, μ, rw, Sk,\ h,\ B,\ \mu,\ r_w,\ Spermeability, thickness, formation volume factor, viscosity, well radius, skin, m², m, m³/m³, Pa·s, m, —

Units: SI

Holds when
  • The flow is transient: the disturbance has not reached the boundaries. We measure the drawdown from the initial pressure pip_i, because the average pressure in an infinite reservoir is not defined.
  • If the drawdown is held constant, the rate falls by the same formula, with a small correction (the rate at constant pressure).

While the drawdown cone expands, the same rate needs an ever larger pressure drop, so the productivity falls slowly. For every tenfold increase in time, the logarithm in the denominator grows by 1.151. In a closed area, the fall in productivity referred to pip_i does not stop, because the area is being depleted. The productivity referred to the average pressure reaches the constant value of pseudo-steady-state flow, where ln⁡(re/rw)−34\ln(r_e/r_w) - \tfrac34 stands in place of ln⁡(rd/rw)\ln(r_d/r_w) (Pseudo-steady-state flow and the shape factor). It is as if the radius of drainage stops at ree−3/4=0.47 rer_e\e^{-3/4} = 0.47\,r_e.

In other unit systems (2)
Metric oilfield units
Jt=0.536 khBμ[ln⁡(rd/rw)+S]J_t = \frac{0.536\,kh}{B\mu\left[\ln(r_d/r_w) + S\right]}

JtJ_t in m³/(d·MPa) at standard conditions, kk in mD, hh in m, μ\mu in mPa·s.

0.536=2π⋅0.08530.536 = 2\pi\cdot0.0853.

Oilfield units
Jt=7.08⋅10−3 khBμ[ln⁡(rd/rw)+S]J_t = \frac{7.08\cdot10^{-3}\,kh}{B\mu\left[\ln(r_d/r_w) + S\right]}

JtJ_t in STB/(d·psi), kk in mD, hh in ft, μ\mu in cP.

7.08⋅10−3=2π⋅1.127⋅10−3=1/141.27.08\cdot10^{-3} = 2\pi\cdot1.127\cdot10^{-3} = 1/141.2.

Productivity index of a well in a closed circle with respect to the initial and to the average pressure0.1110100100010152025Time after start-up t, hJ, m³/(d·MPa)teal — average pressureorange — initial pressuredashed — pseudo-steady state

Graph of the productivity index, from 8 to 26 cubic metres per day per megapascal, against time, from 0.1 to 3000 hours, on a logarithmic scale. Both solid curves start at about 23.7 at 0.1 hour and fall together: 20.2 after an hour and 16.7–16.8 after a day. By 100 hours the orange curve is at 15.5 and the teal one at 15.9. Then the teal curve reaches the dashed horizontal line at 15.7 and stays on it, while the orange one continues to fall: 14.6 by 300 hours, 12.7 by 1000 hours and 9.2 by 3000 hours.

CalculatedCalculated productivity index of the lesson's well (SS = 2) at the centre of a closed circular area of radius 600 m. It is shown with respect to the initial pressure (orange line) and to the average pressure of the area (teal). The dashed horizontal line is the pseudo-steady-state value. The time scale is logarithmic. Up to 100 h, the productivity with respect to the initial pressure is the same as in an infinite reservoir. With respect to the average pressure it is slightly higher from the first hours (by 0.6% after a day, and by 2.4% by 100 h), because the average pressure of a closed area declines from the very start-up.
Worked exampleProductivity after an hour, after a day and after stabilisation
Given (assumed data)
The lesson's well
khkh = 400 mD·m; BμB\mu = 1.375 mPa·s; SS = 2; rwr_w = 0.1 m; ϕμct=3.344⋅10−4\phi\mu c_t = 3.344\cdot10^{-4} MPa⁻¹·mPa·s
Drainage area
a closed circle of radius 600 m, the well at the centre
Solution
  1. The factor is 0.536 kh/(Bμ)=0.536⋅400/1.375=155.90.536\,kh/(B\mu) = 0.536\cdot400/1.375 = 155.9 m³/(d·MPa).
  2. After 1 h: rd=0.089340/(3.344⋅10−4)=30.9r_d = 0.0893\sqrt{40/(3.344\cdot10^{-4})} = 30.9 m, ln⁡(rd/rw)=5.733\ln(r_d/r_w) = 5.733, and Jt=155.9/(5.733+2)=20.16J_t = 155.9/(5.733 + 2) = 20.16 m³/(d·MPa).
  3. After 24 h: rd=151.3r_d = 151.3 m, ln⁡(rd/rw)=7.322\ln(r_d/r_w) = 7.322, and Jt=155.9/(7.322+2)=16.72J_t = 155.9/(7.322 + 2) = 16.72.
  4. After pseudo-steady state is reached: ln⁡(600/0.1)−0.75=7.950\ln(600/0.1) - 0.75 = 7.950, and J=155.9/(7.950+2)=15.67J = 155.9/(7.950 + 2) = 15.67.
  5. The transient productivity becomes equal to the stabilised one when rd=600 e−0.75=283.4r_d = 600\,\e^{-0.75} = 283.4 m, that is, at t=1.781⋅283.42/(4⋅425)=84t = 1.781\cdot283.4^2/(4\cdot425) = 84 h.
Answer: After an hour the productivity is 20.16, after a day 16.72, and after stabilisation 15.67 m³/(d·MPa). A short flow period overestimates it by 29% and 6.7%.

What it means. The reservoir and the skin have not changed in this time. Only the radius of drainage has. So we cannot carry the productivity measured in the first hours of a test over to production. We recalculate it from permeability and skin, for the size of the future drainage area. In a closed area, the productivity referred to the initial pressure keeps falling after 84 h, while the productivity referred to the average pressure stops at 15.67 (see the figure above). The data in this example are assumed for illustration.

When a line source is enough

A summary for practice. The line-source solution and its logarithmic approximation are the working tools of almost all well tests. We have to replace them in only a few cases, but these cases are important.

Where the line-source solution is valid and where it is not
Case
Bottomhole pressure at tD>25t_D > 25 (or 100)
Line source
an error of about 2% (0.5%)
What to do otherwise
—
Case
The first seconds after start-up
Line source
underestimates the pressure drop
What to do otherwise
the finite-radius solution; but on a record the wellbore hides everything
Case
Negative skin
Line source
valid at tDe2S>100t_D\e^{2S} > 100
What to do otherwise
the effective radius or a radial composite model
Case
A neighbouring well, reflections at boundaries
Line source
valid: r≫rwr \gg r_w
What to do otherwise
allow for the wellbore storage of the active well
Case
A hydraulic fracture, a horizontal wellbore
Line source
not valid at the beginning
Case
An accumulation as a “well” in an aquifer
Line source
not valid
What to do otherwise
solutions with a finite radius (Unsteady-state water influx: the van Everdingen–Hurst method)
Case
The disturbance has reached the boundaries
Line source
only together with reflections

The criteria come from comparing with the exact solutions calculated in this lesson and in the lesson Line-source solution and the pressure function.

Terms and symbols

Dimensionless solution
A solution of the diffusivity equation in the variables rDr_D, tDt_D, pDp_D and the dimensionless parameters of the well and the reservoir. It is the same for all wells with the same parameters.
Finite-radius well
A formulation in which the rate is specified at the wall of a cylinder of radius rwr_w. Unlike the line source, it does not take fluid “from inside the wellbore”.
Effective wellbore radius rw′r_w'
The radius of a well without skin that has the same bottomhole pressure, rwe−Sr_w\e^{-S}. It lets us describe a negative skin at the start of flow.
Radius of investigation rir_i
The distance, 4ηt\sqrt{4\eta t}, at which the rate of pressure decline passes through its maximum at the given moment. It is a conventional boundary of the zone covered by the test.
Radius of drainage rdr_d
The radius of steady-state flow with the same bottomhole pressure, 4ηt/γ=0.75 ri\sqrt{4\eta t/\gamma} = 0.75\,r_i.
Transient productivity index JtJ_t
The ratio of the rate to the difference between the initial and bottomhole pressures in transient flow. It falls while the radius of drainage grows.
Radial composite model
A reservoir with a zone of different permeability around the well. When the zone is large, it replaces the skin and gives two levels on the derivative.

Common mistakes and misconceptions

Wrong

“The radius of investigation is a boundary beyond which the pressure has not yet changed.”

In fact

The pressure changes throughout the reservoir immediately after start-up. rir_i is the place where the rate of its decline is just passing through the maximum. In the example of the lesson, rir_i = 202 m after a day, and an accurate gauge in a neighbouring well would notice a response even at 430 m.

Wrong

“A negative skin can simply be subtracted from the solution from the very start-up.”

In fact

Only at late times. At the beginning, an added negative skin gives a “rise” of pressure during production. The correct approach is a well with an effective radius, whose semilog straight line starts at tDe2S≈100t_D\e^{2S} \approx 100. For S=−2S = -2 that is after a few minutes.

Wrong

“The productivity from the first hours of operation is the one at which the well will work.”

In fact

While the radius of drainage grows, the productivity falls. In the example of the lesson, after an hour it is 29% higher than the stabilised one, and after a day it is 7% higher.

Wrong

“If pressure is converted to psi, the constant 141.2 can be used.”

In fact

Only if all the quantities have been converted to oilfield units: rate, thickness, viscosity, compressibility and radius. The check: the dimensionless tDt_D and CDC_D calculated in both systems must be the same.

Wrong

“Skin always acts instantly.”

In fact

A zone with a permeability 3–5 times lower than that of the reservoir behaves like a thin skin when the radius of investigation is about 10 times its radius. A half-metre zone does so after a minute, but a fifteen-metre zone only after half a day (see the advanced section).

In depth: advanced detail

Derivations: flow through a circle, the volume share and the maximum rate

Flow through a circle. In the line-source solution, Δp=qBμ4πkhE1(x)\Delta p = \tfrac{qB\mu}{4\pi kh}E_1(x), where x=r2/(4ηt)x = r^2/(4\eta t). We know that  dE1/ dx=−e−x/x\dd E_1/\dd x = -\e^{-x}/x and  dx/ dr=2x/r\dd x/\dd r = 2x/r. So the pressure gradient is ∂p/∂r=−∂Δp/∂r=qBμ2πkh⋅e−xr\partial p/\partial r = -\partial\Delta p/\partial r = \tfrac{qB\mu}{2\pi kh}\cdot\tfrac{\e^{-x}}{r}. By Darcy's law, the flow through a cylinder of radius rr is 2πrhkμ ∂p∂r=qB e−x\tfrac{2\pi rhk}{\mu}\,\tfrac{\partial p}{\partial r} = qB\,\e^{-x} at reservoir conditions. That is q e−xq\,\e^{-x} at standard conditions.

Volume share. The elastic storage released inside radius RR (the fluid and rock expanding as the pressure falls) is ϕcth∫0R2πr Δp  dr\phi c_th\int_0^R 2\pi r\,\Delta p\,\dd r. We substitute u=r2/(4ηt)u = r^2/(4\eta t), which gives 2πr  dr=4πηt  du2\pi r\,\dd r = 4\pi\eta t\,\dd u. The integral becomes qBt∫0XE1(u)  duqBt\int_0^X E_1(u)\,\dd u. Integrating by parts gives ∫0XE1(u)  du=XE1(X)+1−e−X\int_0^X E_1(u)\,\dd u = XE_1(X) + 1 - \e^{-X}. As X→∞X \to \infty this is 1, which is the whole withdrawn volume qBtqBt. So the material balance is satisfied.

The maximum rate of pressure decline. The derivative of Δp\Delta p with respect to time is qBμ4πkh⋅e−a/tt\tfrac{qB\mu}{4\pi kh}\cdot\tfrac{\e^{-a/t}}{t}, where a=r2/(4η)a = r^2/(4\eta). Its derivative with respect to tt is proportional to e−a/t(a/t−1)/t2\e^{-a/t}(a/t - 1)/t^2. This is zero at t=at = a, that is, when r2=4ηtr^2 = 4\eta t.

A skin zone of finite size: when the skin is “instantaneous”

Skin treated as an infinitely thin zone assumes two things: the changed permeability is concentrated right at the wall, and fluid does not accumulate in this zone. A real zone of radius rsr_s and permeability ksk_s has its own transient. As long as the disturbance has not gone far beyond the zone, the well “sees” the permeability of the zone. The exact solution is the radial composite model of the reservoir: inside rsr_s the permeability is ksk_s, outside it is kk, and at the boundary between the zones the pressure and the flow rate are continuous (they do not jump).

A well with a zone of different permeability: the Laplace transform
pˉwD(s)=K0(σ)+ρ I0(σ)s κσ[K1(σ)−ρ I1(σ)],σ=s/κ\bar p_{wD}(s) = \frac{K_0(\sigma) + \rho\,I_0(\sigma)}{s\,\kappa\sigma\left[K_1(\sigma) - \rho\,I_1(\sigma)\right]},\qquad \sigma = \sqrt{s/\kappa}
where:
  • κ\kappathe ratio ks/kk_s/k of the permeability of the zone to that of the reservoir, —
  • ρ\rhoa coefficient found from the continuity of pressure and flow rate at the boundary of the zone R=rs/rwR = r_s/r_w: ρ=−uλK0(σR)−κσK1(σR)uλI0(σR)+κσI1(σR)\rho = -\dfrac{u\lambda K_0(\sigma R) - \kappa\sigma K_1(\sigma R)}{u\lambda I_0(\sigma R) + \kappa\sigma I_1(\sigma R)}, u=su = \sqrt s, λ=K1(uR)/K0(uR)\lambda = K_1(uR)/K_0(uR), —
  • I0, I1, K0, K1I_0,\ I_1,\ K_0,\ K_1modified Bessel functions, —

Units: no units; pDp_D is referred to the permeability kk of the outer zone

Holds when
  • The flow is single-phase, porosity, compressibility and viscosity are the same in both zones, and there is no wellbore storage.

At κ=1\kappa = 1 we get the finite-radius solution. At early times, if the zone is large enough, the derivative goes to the level 0.5/κ0.5/\kappa (the flow goes through the zone). At late times it goes to 0.5, and the pressure goes to pD+Sp_D + S with the Hawkins skin S=(1/κ−1)ln⁡RS = (1/\kappa - 1)\ln R (the Hawkins formula).

Pressure derivative of a well with a finite-size zone of reduced permeability0.00010.0111000.5125Time after start-up t, hΔp′ / mₑorange — 0.5 m, k/5teal — 15 m, k/3grey — no zone

Graph on a log–log scale. Time runs from 0.0001 to 100 hours. The ratio of the derivative to the plateau runs from 0.3 to 6. The grey dashed curve, for the well without a zone, rises from 0.78 and approaches one by hundredths of an hour: 0.95 at 0.001 hour and 0.99 at 0.01 hour. The orange curve, for the half-metre zone, rises to 3.76 near 0.0005 hour and quickly falls: 1.6 at 0.003 hour and 1.05 at 0.02 hour. The teal curve, for the fifteen-metre zone, rises to the level 3 and stays near it from about 0.01 to 0.3 hour. Then it falls: 2.1 at one hour, 1.26 at 3 hours, 1.06 at 10 hours, and almost one by 100 hours.

CalculatedCalculated pressure derivative of the lesson's well with a zone of reduced permeability, divided by the radial-flow plateau mem_e, without wellbore storage. One zone has a radius of 0.5 m and permeability k/5k/5. The other has a radius of 15 m and permeability k/3k/3. The grey dashed line is the well without a zone, and the light line is the plateau level. Both scales are logarithmic.
When a zone of altered permeability begins to behave as a thin skin
Zone
damage, 0.5 m
Permeability
k/5k/5
Skin
6.4
Derivative within 5% of the plateau
71 s
ri/rsr_i/r_s at that moment
11.6
Zone
zone, 15 m
Permeability
k/3k/3
Skin
10.0
Derivative within 5% of the plateau
11.7 h
ri/rsr_i/r_s at that moment
9.4

The lesson's well: η\eta = 425 m²/h, rwr_w = 0.1 m. The skin is found by the Hawkins formula. The values are calculated with the composite model, without wellbore storage.

Here is the rule that follows from the calculation. A zone with a permeability 3–5 times lower than that of the reservoir acts as a thin skin when the radius of investigation is about ten times its radius (the derivative is within 5% of the plateau). The stronger the contrast, the longer it takes: at k/10k/10 we need about 20 rs20\,r_s, while a zone of improved permeability “disappears” already by 55–6 rs6\,r_s (calculated with the same model). A half-metre zone of mud damage “disappears” in a minute, long before wellbore storage ends, so the formula with a skin is accurate for such zones. A zone of tens of metres gives two levels on the derivative: first 0.5/κ0.5/\kappa, then 0.5. Such a zone may be water near a former injection well, condensate that has dropped out near a gas-condensate well (Retrograde condensation, wax, asphaltenes and high-pressure fluids), or gas released below the bubble point pressure (the pressure below which gas comes out of the oil). This is what a radial composite reservoir looks like. We cannot process such a record as radial flow with a skin, because the first plateau would give the permeability of the zone instead of that of the reservoir.

Connections to other topics

Check yourself

  1. 1

    A well of radius 0.1 m, a reservoir with a hydraulic diffusivity of 360 m²/h. How long after start-up does 99% of the rate pass through the wall of the well in the line-source solution?

    1. A.About 2.5 s
    2. B.Only after pseudo-steady state is reached
    3. C.About 2.5 min
    4. D.About 2.5 h
    Show the answer

    Correct answer: A. About 2.5 s

    The share of the rate, e−1/(4tD)\e^{-1/(4t_D)}, equals 0.99 at tD=24.9t_D = 24.9. The time is t=tDrw2/η=24.9⋅0.01/360=6.9⋅10−4t = t_D r_w^2/\eta = 24.9\cdot0.01/360 = 6.9\cdot10^{-4} h, that is, 2.5 s. The difference between the line source and the finite-radius well lasts only for the first seconds.

  2. 2

    A report gives a wellbore storage coefficient of 0.02 bbl/psi. Find CC in m³/MPa and CDC_D for ϕ\phi = 0.2, ct=1.5⋅10−3c_t = 1.5\cdot10^{-3} MPa⁻¹, hh = 15 m, rwr_w = 0.108 m.

    Show the answer

    C=0.02⋅23.06=0.461C = 0.02\cdot23.06 = 0.461 m³/MPa. The denominator is 2πϕcthrw2=2π⋅0.2⋅1.5⋅10−3⋅15⋅0.1082=3.30⋅10−42\pi\phi c_thr_w^2 = 2\pi\cdot0.2\cdot1.5\cdot10^{-3}\cdot15\cdot0.108^2 = 3.30\cdot10^{-4} m³/MPa. CD=0.461/(3.30⋅10−4)≈1400C_D = 0.461/(3.30\cdot10^{-4}) \approx 1400. In oilfield units the same number comes out, and this is the check of the conversion.

  3. 3

    After a treatment the skin of a well is S=−3S = -3. From what dimensionless time (based on the wellbore radius) can the semilog formula be used with an error of about 0.5%?

    1. A.tD≈25t_D \approx 25
    2. B.tD≈100t_D \approx 100
    3. C.tD≈40,000t_D \approx 40{,}000
    4. D.tD≈4⋅108t_D \approx 4\cdot10^8
    Show the answer

    Correct answer: C. tD≈40,000t_D \approx 40{,}000

    The well behaves like a well of radius rw′=rwe3r_w' = r_w\e^{3}. For this well, the condition tD′>100t_D' > 100 means tDe2S>100t_D\e^{2S} > 100, that is, tD>100 e6≈40,000t_D > 100\,\e^{6} \approx 40{,}000. For an ordinary well this is minutes, not seconds.

  4. 4

    The flow period lasted 12 h in a reservoir with η\eta = 800 m²/h. Find the radius of investigation, the radius of drainage and the radius inside which 95% of the withdrawn volume is supplied. At what distance must a fault be for the derivative to rise by 10% by the end of the flow period?

    Show the answer

    ri=4⋅800⋅12=196r_i = \sqrt{4\cdot800\cdot12} = 196 m, rd=0.749⋅196=147r_d = 0.749\cdot196 = 147 m, and 95% of the volume is supplied from within 1.335⋅196=2621.335\cdot196 = 262 m. The derivative step is e−L2/(ηt)=0.1\e^{-L^2/(\eta t)} = 0.1 at L=ηtln⁡10=0.759 ri=149L = \sqrt{\eta t\ln10} = 0.759\,r_i = 149 m. So the fault must be no farther than about 150 m.

  5. 5

    Why is the productivity index of a new well over the first hour of work higher than after a month, if the reservoir and the skin have not changed?

    1. A.The oil viscosity falls
    2. B.The radius of drainage grows, so the same rate needs a larger pressure drop
    3. C.The skin grows
    4. D.The permeability of the reservoir falls
    Show the answer

    Correct answer: B. The radius of drainage grows, so the same rate needs a larger pressure drop

    The denominator of the transient productivity index contains ln⁡(rd/rw)+S\ln(r_d/r_w) + S, and the radius of drainage rdr_d grows as t\sqrt t. In the example of the lesson, the productivity after an hour is 29% higher than the stabilised one. So we recalculate the productivity from a short test for the future drainage area.

  6. 6

    Around a well of radius 0.1 m there is a zone of radius 3 m with a permeability four times lower than that of the reservoir. The hydraulic diffusivity of the reservoir is 200 m²/h. After how long can the zone be regarded as a thin skin?

    Show the answer

    By the rule of the lesson, the zone acts as a thin skin when the radius of investigation is about ten times the radius of the zone, that is, about 30 m: t≈ri2/(4η)=900/800≈1.1t \approx r_i^2/(4\eta) = 900/800 \approx 1.1 h. Before that, the derivative is above the radial-flow plateau, and the permeability found from it would be too low. The skin of such a zone by the Hawkins formula is 3ln⁡30≈10.23\ln 30 \approx 10.2.

Updated: 19 October 2026